Problem

Updating to FlowAP fails and you receive the below errors message:

...

Solution

The error is being thrown by the Bundle Installation script because it is trying to set an Inactive Subsidiary on the custrecord_sta_flowap_cross_sub_vend field. To resolve this please do the following:

  1. FlowAP > FlowAP Configuration > Staria FlowAP Subsidiary Setup

  2. Edit the View and add the following Field:
    Subsidiary: Inactive

  3. Save

  4. Identify the Inactive sub from the list

  5. Edit the Inflow Preference

  6. Set Inactive = T then Save

  7. Setup > Company > General Preferences > Custom Preferences

  8. INFLOW: LIST OF SUBSIDIARY IDS TO USE APPROVALS (DEPRECATED) > remove the Internal ID of the inactive Subsidiary then Save

  9. Perform the Bundle Update again